冠亚rb88体育(中国)科技有限公司

ZD1C Contact Resistance Tester (100A Current)




ZD1C Contact Resistance Tester 100A

INTRODUCTION

The risk of overheating is becoming more serious due to the fact that today’s distribution networks have to carry heavier loads. Checking contact resistance at regular intervals detects faults before they cause overheating. Contact resistance tester is used to measure contact resistances of circuit breakers, disconnecting switches, earthing switches, bus joints, bushing contact joints and welding joints. Also for any low resistance measuring application. The tester provide 100A DC current, and the voltage measurement gets the voltage of tested object.The method of calculate resistance according to Ohm's law. (R=U/I)
 
FEATURES

Setting current output time between 1s to 60s.
Save the device’s series number, for checking the result conveniently.
Display output current,output time and resistance during testing.
Saving 100 test results in tester memory.
Built-in clock record the date.
The stored result includes device’s number, testing time and resistance.
 

SPECIFICATIONS
ZD1C
Test current: 100A
Output power: 1kW
Measuring range: 0.1μΩ to 20000μΩ
Accuracy: ± 0.5% rdg ± 0.2μΩ
Range 0.1μΩ to 999.9μΩ, 
Resolution:0.1μΩ

Range 1000μΩ to 20000μΩ,  
Resolution:1μΩ
Ammeter accuracy:
± 0.5% rdg ±0.1A
Dimensions: 403×330×178mm    
Weight: 7kg
General
Memory capacity: 100 results
Power supply: 198 to 264VAC  
             47 to 63Hz
Environment:-20 to 50℃
Humidity ≤90%RH   Non-condensing
 
 
 

Baidu
sogou